Test Date: 2015-08-17 09:36
Analysis date: 2016-05-26 01:44
FullQualification M2074
Module ID Test Date Analysis Test Type Grade Pixel Defects ROCs < 1% ROCs > 1% ROCs > 4% Noise Trimming PHCalibration I(150V) I_rec(150V) IV Slope Temperature initial Current Comments
M2074 2015-08-17 09:36 2016-03-24 23:04 m20_1 A 26 16 0 0 0 0 0 -1.0 -1.0 0.0 -20 0.0
M2074 2015-08-17 09:36 2016-03-24 23:04 m20_2 A 33 16 0 0 1 0 0 2e-08 7.6e-07 1.59 -20 0.0
M2074 2015-08-17 09:36 2016-03-24 23:04 p17_1 A 39 16 0 0 0 0 0 6.2e-07 6.2e-07 1.12 17 0.0
M2074 ModuleQualification_Temperature
M2074 ModuleQualification_Humidity
M2074 ModuleQualification_SumOfCurrents
M2074 ModuleFulltestPxar_m20_1

Overview

M2074 ModuleFulltest_TemperatureCycle
nCycles nCycles 10 #
CycleTempLow CycleTempLow -25
CycleTempHigh CycleTempHigh 17
M2074 ModuleFulltestPxar_m20_2

Overview

M2074 ModuleFulltestPxar_p17_1

Overview

MoReWeb-v1.0.0-5-g82d9ff6 on branch psi46master