Test Date: 2015-07-07 08:07
Chip 5
X-ray Calibration - Target Zn Method Spectrum Chip C5
Center Center of Peak 50.17 ± 0.07 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 12.26
Rate Rate 330.80 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C5
Center Center of Peak 101.33 ± 0.08 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 6.0
Rate Rate 475.80 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C5
Center Center of Peak 128.93 ± 0.12 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 4.28
Rate Rate 248.20 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C5
Center Center of Peak 147.18 ± 0.16 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 5.46
Rate Rate 155.50 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C5
Slope Slope 47.185 ± 0.164 nElectrons/VCal
Offset Offset 73.908 ± 19.099 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C5
Rate Rate 330.80 kHz/cm²
NTrigs N Trig 5916644 Trigger
NHits N Hits 30533 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C5
Rate Rate 475.80 kHz/cm²
NTrigs N Trig 5916569 Trigger
NHits N Hits 43915 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C5
Rate Rate 248.20 kHz/cm²
NTrigs N Trig 5916456 Trigger
NHits N Hits 22909 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C5
Rate Rate 155.50 kHz/cm²
NTrigs N Trig 5916385 Trigger
NHits N Hits 14351 Hits