Test Date: 2015-07-07 08:07
Chip 8
X-ray Calibration - Target Zn Method Spectrum Chip C8
Center Center of Peak 45.29 ± 0.11 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 28.29
Rate Rate 265.00 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C8
Center Center of Peak 91.63 ± 0.08 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 13.43
Rate Rate 439.30 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C8
Center Center of Peak 117.01 ± 0.12 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 6.36
Rate Rate 237.20 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C8
Center Center of Peak 134.2 ± 0.17 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 5.37
Rate Rate 149.80 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C8
Slope Slope 50.987 ± 0.197 nElectrons/VCal
Offset Offset 184.503 ± 20.704 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C8
Rate Rate 265.00 kHz/cm²
NTrigs N Trig 5916644 Trigger
NHits N Hits 24464 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C8
Rate Rate 439.30 kHz/cm²
NTrigs N Trig 5916569 Trigger
NHits N Hits 40549 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C8
Rate Rate 237.20 kHz/cm²
NTrigs N Trig 5916456 Trigger
NHits N Hits 21894 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C8
Rate Rate 149.80 kHz/cm²
NTrigs N Trig 5916385 Trigger
NHits N Hits 13826 Hits