Test Date: 2019-05-03 10:27
Analysis date: 2019-05-03 15:24
Chip 4
X-ray Calibration - Target Zn Method Spectrum Chip C4
Center Center of Peak 36.66 ± 1.18 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.48
Rate Rate 134.50 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C4
Center Center of Peak 108.95 ± 0.11 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 2.42
Rate Rate 340.80 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C4
Center Center of Peak 135.05 ± 0.15 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 1.54
Rate Rate 213.80 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C4
Center Center of Peak 151.8 ± 0.2 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 1.88
Rate Rate 140.70 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C4
Slope Slope 50.312 ± 0.241 nElectrons/VCal
Offset Offset -628.3 ± 30.124 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C4
Rate Rate 134.50 kHz/cm²
NTrigs N Trig 5915949 Trigger
NHits N Hits 12410 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C4
Rate Rate 340.80 kHz/cm²
NTrigs N Trig 5915789 Trigger
NHits N Hits 31454 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C4
Rate Rate 213.80 kHz/cm²
NTrigs N Trig 5915976 Trigger
NHits N Hits 19730 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C4
Rate Rate 140.70 kHz/cm²
NTrigs N Trig 5915857 Trigger
NHits N Hits 12986 Hits
MoReWeb-v1.1.0 on branch AnalyzeNewXPixelAlive