Test Date: 2015-12-11 15:01
Analysis date: 2015-12-15 10:00
Chip 12
X-ray Calibration - Target Zn Method Spectrum Chip C12
Center Center of Peak 46.77 ± 0.11 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.41
Rate Rate 122.70 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C12
Center Center of Peak 92.47 ± 0.07 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 2.93
Rate Rate 392.60 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C12
Center Center of Peak 116.47 ± 0.09 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 4.4
Rate Rate 219.30 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C12
Center Center of Peak 132.09 ± 0.12 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 3.61
Rate Rate 138.70 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C12
Slope Slope 53.886 ± 0.11 nElectrons/VCal
Offset Offset -123.712 ± 10.26 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C12
Rate Rate 122.70 kHz/cm²
NTrigs N Trig 5921517 Trigger
NHits N Hits 11337 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C12
Rate Rate 392.60 kHz/cm²
NTrigs N Trig 5922269 Trigger
NHits N Hits 36269 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C12
Rate Rate 219.30 kHz/cm²
NTrigs N Trig 5922329 Trigger
NHits N Hits 20258 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C12
Rate Rate 138.70 kHz/cm²
NTrigs N Trig 5922180 Trigger
NHits N Hits 12810 Hits
MoReWeb-v0.6.7-111-gcc5e703 on branch 20151208_Readback