Test Date: 2015-10-27 11:11
Analysis date: 2015-10-27 13:37
Chip 8
X-ray Calibration - Target Zn Method Spectrum Chip C8
Center |
Center of Peak |
47.36 ± 0.07 |
Vcal |
TargetEnergy |
Energy of target Zn |
8638.91 |
eV |
TargetNElectrons |
Energy of target Zn |
2399.7 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
1.18 |
|
Rate |
Rate |
180.30 |
kHz/cm² |
X-ray Calibration - Target Mo Method Spectrum Chip C8
Center |
Center of Peak |
94.21 ± 0.1 |
Vcal |
TargetEnergy |
Energy of target Mo |
17479.37 |
eV |
TargetNElectrons |
Energy of target Mo |
4855.38 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
1.61 |
|
Rate |
Rate |
433.00 |
kHz/cm² |
X-ray Calibration - Target Ag Method Spectrum Chip C8
Center |
Center of Peak |
119.53 ± 0.17 |
Vcal |
TargetEnergy |
Energy of target Ag |
22162.92 |
eV |
TargetNElectrons |
Energy of target Ag |
6156.37 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
2.82 |
|
Rate |
Rate |
233.30 |
kHz/cm² |
X-ray Calibration - Target Sn Method Spectrum Chip C8
Center |
Center of Peak |
136.71 ± 0.22 |
Vcal |
TargetEnergy |
Energy of target Sn |
25271.36 |
eV |
TargetNElectrons |
Energy of target Sn |
7019.82 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
2.8 |
|
Rate |
Rate |
150.20 |
kHz/cm² |
X-ray Calibration - Vcal Calibration Method Spectrum Chip C8
Slope |
Slope |
51.07 ± 0.256 |
nElectrons/VCal |
Offset |
Offset |
45.044 ± 27.353 |
nElectrons |
X-ray Hit Map - Target Zn Method Spectrum Chip C8
Rate |
Rate |
180.30 |
kHz/cm² |
NTrigs |
N Trig |
5919600 |
Trigger |
NHits |
N Hits |
16648 |
Hits |
X-ray Hit Map - Target Mo Method Spectrum Chip C8
Rate |
Rate |
433.00 |
kHz/cm² |
NTrigs |
N Trig |
5918900 |
Trigger |
NHits |
N Hits |
39985 |
Hits |
X-ray Hit Map - Target Ag Method Spectrum Chip C8
Rate |
Rate |
233.30 |
kHz/cm² |
NTrigs |
N Trig |
5919621 |
Trigger |
NHits |
N Hits |
21547 |
Hits |
X-ray Hit Map - Target Sn Method Spectrum Chip C8
Rate |
Rate |
150.20 |
kHz/cm² |
NTrigs |
N Trig |
5919624 |
Trigger |
NHits |
N Hits |
13874 |
Hits |
MoReWeb-v0.6.7-13-gc9cb95f
on branch psi46master