Test Date: 2015-07-07 08:07
Chip 11
X-ray Calibration - Target Zn Method Spectrum Chip C11
Center Center of Peak 49.07 ± 0.09 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 8.28
Rate Rate 289.20 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C11
Center Center of Peak 103.86 ± 0.09 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 4.9
Rate Rate 455.50 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C11
Center Center of Peak 132.27 ± 0.13 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 6.3
Rate Rate 241.30 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C11
Center Center of Peak 151.61 ± 0.16 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 5.18
Rate Rate 150.70 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C11
Slope Slope 45.451 ± 0.16 nElectrons/VCal
Offset Offset 136.353 ± 19.463 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C11
Rate Rate 289.20 kHz/cm²
NTrigs N Trig 5916644 Trigger
NHits N Hits 26693 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C11
Rate Rate 455.50 kHz/cm²
NTrigs N Trig 5916569 Trigger
NHits N Hits 42045 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C11
Rate Rate 241.30 kHz/cm²
NTrigs N Trig 5916456 Trigger
NHits N Hits 22268 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C11
Rate Rate 150.70 kHz/cm²
NTrigs N Trig 5916385 Trigger
NHits N Hits 13909 Hits