Test Date: 2015-07-07 08:07
Chip 2
X-ray Calibration - Target Zn Method Spectrum Chip C2
Center Center of Peak 49.08 ± 0.11 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 14.07
Rate Rate 187.10 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C2
Center Center of Peak 102.39 ± 0.09 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 8.65
Rate Rate 304.40 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C2
X-ray Calibration - Target Sn Method Spectrum Chip C2
Center Center of Peak 149.26 ± 0.15 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 5.6
Rate Rate 120.10 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C2
X-ray Hit Map - Target Zn Method Spectrum Chip C2
Rate Rate 187.10 kHz/cm²
NTrigs N Trig 5920420 Trigger
NHits N Hits 17280 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C2
Rate Rate 304.40 kHz/cm²
NTrigs N Trig 5920389 Trigger
NHits N Hits 28112 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C2
X-ray Hit Map - Target Sn Method Spectrum Chip C2
Rate Rate 120.10 kHz/cm²
NTrigs N Trig 5919695 Trigger
NHits N Hits 11090 Hits