Test Date: 2015-07-07 08:07
Chip 12
X-ray Calibration - Target Zn Method Spectrum Chip C12
Center Center of Peak 51.38 ± 0.07 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 15.66
Rate Rate 308.90 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C12
Center Center of Peak 104.03 ± 0.07 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 9.91
Rate Rate 445.70 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C12
X-ray Calibration - Target Sn Method Spectrum Chip C12
Center Center of Peak 150.3 ± 0.12 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 6.4
Rate Rate 157.60 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C12
X-ray Hit Map - Target Zn Method Spectrum Chip C12
Rate Rate 308.90 kHz/cm²
NTrigs N Trig 5920420 Trigger
NHits N Hits 28527 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C12
Rate Rate 445.70 kHz/cm²
NTrigs N Trig 5920389 Trigger
NHits N Hits 41164 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C12
X-ray Hit Map - Target Sn Method Spectrum Chip C12
Rate Rate 157.60 kHz/cm²
NTrigs N Trig 5919695 Trigger
NHits N Hits 14554 Hits