Test Date: 2015-07-07 08:07
Chip 1
X-ray Calibration - Target Zn Method Spectrum Chip C1
Center Center of Peak 52.11 ± 0.07 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 32.95
Rate Rate 257.60 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C1
Center Center of Peak 102.15 ± 0.08 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 13.56
Rate Rate 370.30 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C1
X-ray Calibration - Target Sn Method Spectrum Chip C1
Center Center of Peak 148.9 ± 0.12 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 8.56
Rate Rate 148.10 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C1
X-ray Hit Map - Target Zn Method Spectrum Chip C1
Rate Rate 257.60 kHz/cm²
NTrigs N Trig 5920420 Trigger
NHits N Hits 23794 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C1
Rate Rate 370.30 kHz/cm²
NTrigs N Trig 5920389 Trigger
NHits N Hits 34200 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C1
X-ray Hit Map - Target Sn Method Spectrum Chip C1
Rate Rate 148.10 kHz/cm²
NTrigs N Trig 5919695 Trigger
NHits N Hits 13674 Hits