Test Date: 2015-06-05 18:06
Chip 9
X-ray Calibration - Target Zn Method Spectrum Chip C9
Center Center of Peak 55.03 ± 0.09 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 50.63
Rate Rate 340.40 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C9
Center Center of Peak 107.9 ± 0.07 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 28.16
Rate Rate 469.60 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C9
Center Center of Peak 136.49 ± 0.11 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 18.0
Rate Rate 244.50 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C9
Center Center of Peak 155.91 ± 0.14 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 10.18
Rate Rate 151.80 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C9
Slope Slope 45.207 ± 0.132 nElectrons/VCal
Offset Offset -21.284 ± 16.345 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C9
Rate Rate 340.40 kHz/cm²
NTrigs N Trig 5913115 Trigger
NHits N Hits 31404 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C9
Rate Rate 469.60 kHz/cm²
NTrigs N Trig 5913243 Trigger
NHits N Hits 43323 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C9
Rate Rate 244.50 kHz/cm²
NTrigs N Trig 5913128 Trigger
NHits N Hits 22550 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C9
Rate Rate 151.80 kHz/cm²
NTrigs N Trig 5912980 Trigger
NHits N Hits 14004 Hits