Test Date: 2015-06-05 18:06
Chip 7
X-ray Calibration - Target Zn Method Spectrum Chip C7
Center Center of Peak 55.07 ± 0.11 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 30.61
Rate Rate 339.00 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C7
Center Center of Peak 106.83 ± 0.09 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 19.76
Rate Rate 481.10 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C7
Center Center of Peak 136.34 ± 0.13 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 9.63
Rate Rate 251.90 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C7
Center Center of Peak 156.11 ± 0.15 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 7.23
Rate Rate 156.30 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C7
Slope Slope 43.96 ± 0.146 nElectrons/VCal
Offset Offset 159.735 ± 18.306 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C7
Rate Rate 339.00 kHz/cm²
NTrigs N Trig 5913115 Trigger
NHits N Hits 31275 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C7
Rate Rate 481.10 kHz/cm²
NTrigs N Trig 5913243 Trigger
NHits N Hits 44381 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C7
Rate Rate 251.90 kHz/cm²
NTrigs N Trig 5913128 Trigger
NHits N Hits 23238 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C7
Rate Rate 156.30 kHz/cm²
NTrigs N Trig 5912980 Trigger
NHits N Hits 14416 Hits