Test Date: 2015-06-05 18:06
Chip 3
X-ray Calibration - Target Zn Method Spectrum Chip C3
Center Center of Peak 52.41 ± 0.08 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 31.46
Rate Rate 302.10 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C3
Center Center of Peak 103.43 ± 0.08 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 18.4
Rate Rate 457.80 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C3
Center Center of Peak 130.95 ± 0.12 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 8.03
Rate Rate 237.80 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C3
Center Center of Peak 149.03 ± 0.15 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 7.04
Rate Rate 151.50 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C3
Slope Slope 47.412 ± 0.16 nElectrons/VCal
Offset Offset -49.016 ± 19.12 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C3
Rate Rate 302.10 kHz/cm²
NTrigs N Trig 5913115 Trigger
NHits N Hits 27866 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C3
Rate Rate 457.80 kHz/cm²
NTrigs N Trig 5913243 Trigger
NHits N Hits 42226 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C3
Rate Rate 237.80 kHz/cm²
NTrigs N Trig 5913128 Trigger
NHits N Hits 21934 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C3
Rate Rate 151.50 kHz/cm²
NTrigs N Trig 5912980 Trigger
NHits N Hits 13971 Hits