Test Date: 2015-04-23 11:04
Chip 3
X-ray Calibration - Target Cu Method Spectrum Chip C3
Center Center of Peak 42.22 ± 0.16 Vcal
TargetEnergy Energy of target Cu 8047.82 eV
TargetNElectrons Energy of target Cu 2235.51 nElectrons
Chi2PerNDF Chi^2 per NDF 30.87
Rate Rate 297.30 kHz/cm²
X-ray Calibration - Target Zn Method Spectrum Chip C3
Center Center of Peak 46.01 ± 0.08 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 31.71
Rate Rate 329.30 kHz/cm²
X-ray Calibration - Target Br Method Spectrum Chip C3
Center Center of Peak 62.12 ± 0.08 Vcal
TargetEnergy Energy of target Br 11924.36 eV
TargetNElectrons Energy of target Br 3312.32 nElectrons
Chi2PerNDF Chi^2 per NDF 24.87
Rate Rate 531.50 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C3
Center Center of Peak 95.71 ± 0.07 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 14.06
Rate Rate 531.90 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C3
Center Center of Peak 119.97 ± 0.13 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 10.1
Rate Rate 286.60 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C3
Center Center of Peak 139.38 ± 0.18 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 8.11
Rate Rate 177.30 kHz/cm²
X-ray Calibration - Target Ba Method Spectrum Chip C3
Center Center of Peak 176.08 ± 0.47 Vcal
TargetEnergy Energy of target Ba 32193.26 eV
TargetNElectrons Energy of target Ba 8942.57 nElectrons
Chi2PerNDF Chi^2 per NDF 4.74
Rate Rate 62.90 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C3
Slope Slope 49.96 ± 0.077 nElectrons/VCal
Offset Offset 93.696 ± 6.904 nElectrons
X-ray Hit Map - Target Cu Method Spectrum Chip C3
Rate Rate 297.30 kHz/cm²
NTrigs N Trig 5911192 Trigger
NHits N Hits 27411 Hits
X-ray Hit Map - Target Zn Method Spectrum Chip C3
Rate Rate 329.30 kHz/cm²
NTrigs N Trig 5911311 Trigger
NHits N Hits 30369 Hits
X-ray Hit Map - Target Br Method Spectrum Chip C3
Rate Rate 531.50 kHz/cm²
NTrigs N Trig 5910896 Trigger
NHits N Hits 49009 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C3
Rate Rate 531.90 kHz/cm²
NTrigs N Trig 5911879 Trigger
NHits N Hits 49051 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C3
Rate Rate 286.60 kHz/cm²
NTrigs N Trig 5912034 Trigger
NHits N Hits 26432 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C3
Rate Rate 177.30 kHz/cm²
NTrigs N Trig 5909390 Trigger
NHits N Hits 16341 Hits
X-ray Hit Map - Target Ba Method Spectrum Chip C3
Rate Rate 62.90 kHz/cm²
NTrigs N Trig 5911628 Trigger
NHits N Hits 5803 Hits