Test Date: 2015-05-26 14:05
Chip 3
X-ray Calibration - Target Zn Method Spectrum Chip C3
Center Center of Peak 49.49 ± 0.08 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 7.12
Rate Rate 348.70 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C3
Center Center of Peak 104.59 ± 0.08 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 3.72
Rate Rate 547.60 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C3
Center Center of Peak 134.45 ± 0.11 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 4.48
Rate Rate 293.60 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C3
Center Center of Peak 154.62 ± 0.14 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 5.09
Rate Rate 185.30 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C3
Slope Slope 43.347 ± 0.128 nElectrons/VCal
Offset Offset 322.913 ± 15.836 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C3
Rate Rate 348.70 kHz/cm²
NTrigs N Trig 5911837 Trigger
NHits N Hits 32161 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C3
Rate Rate 547.60 kHz/cm²
NTrigs N Trig 5911915 Trigger
NHits N Hits 50503 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C3
Rate Rate 293.60 kHz/cm²
NTrigs N Trig 5911947 Trigger
NHits N Hits 27079 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C3
Rate Rate 185.30 kHz/cm²
NTrigs N Trig 5911790 Trigger
NHits N Hits 17088 Hits