Test Date: 2015-03-31 12:03
Chip 13
X-ray Calibration - Target Cu Method Spectrum Chip C13
Center Center of Peak 50.67 ± 0.09 Vcal
TargetEnergy Energy of target Cu 8047.82 eV
TargetNElectrons Energy of target Cu 2235.51 nElectrons
Chi2PerNDF Chi^2 per NDF 1.59
Rate Rate 199.60 kHz/cm²
X-ray Calibration - Target Zn Method Spectrum Chip C13
Center Center of Peak 52.9 ± 0.08 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 2.04
Rate Rate 212.00 kHz/cm²
X-ray Calibration - Target Br Method Spectrum Chip C13
Center Center of Peak 67.76 ± 0.12 Vcal
TargetEnergy Energy of target Br 11924.36 eV
TargetNElectrons Energy of target Br 3312.32 nElectrons
Chi2PerNDF Chi^2 per NDF 2.62
Rate Rate 356.60 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C13
Center Center of Peak 97.85 ± 0.08 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 2.7
Rate Rate 380.90 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C13
Center Center of Peak 123.22 ± 0.12 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 3.16
Rate Rate 214.90 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C13
Center Center of Peak 140.87 ± 0.15 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 2.89
Rate Rate 141.40 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C13
Slope Slope 50.58 ± 0.183 nElectrons/VCal
Offset Offset -91.181 ± 20.583 nElectrons
X-ray Hit Map - Target Cu Method Spectrum Chip C13
Rate Rate 199.60 kHz/cm²
NTrigs N Trig 5910172 Trigger
NHits N Hits 18399 Hits
X-ray Hit Map - Target Zn Method Spectrum Chip C13
Rate Rate 212.00 kHz/cm²
NTrigs N Trig 5908882 Trigger
NHits N Hits 19541 Hits
X-ray Hit Map - Target Br Method Spectrum Chip C13
Rate Rate 356.60 kHz/cm²
NTrigs N Trig 3630153 Trigger
NHits N Hits 20192 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C13
Rate Rate 380.90 kHz/cm²
NTrigs N Trig 5910007 Trigger
NHits N Hits 35120 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C13
Rate Rate 214.90 kHz/cm²
NTrigs N Trig 5911383 Trigger
NHits N Hits 19814 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C13
Rate Rate 141.40 kHz/cm²
NTrigs N Trig 5911763 Trigger
NHits N Hits 13038 Hits