Test Date: 2015-06-04 14:06
Chip 9
X-ray Calibration - Target Zn Method Spectrum Chip C9
Center Center of Peak 52.26 ± 0.12 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 5.34
Rate Rate 315.90 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C9
Center Center of Peak 106.44 ± 0.08 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 4.13
Rate Rate 466.20 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C9
Center Center of Peak 135.39 ± 0.11 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 4.09
Rate Rate 245.40 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C9
Center Center of Peak 153.29 ± 0.13 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 4.42
Rate Rate 158.10 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C9
Slope Slope 45.21 ± 0.088 nElectrons/VCal
Offset Offset 39.777 ± 9.291 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C9
Rate Rate 315.90 kHz/cm²
NTrigs N Trig 5913615 Trigger
NHits N Hits 29146 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C9
Rate Rate 466.20 kHz/cm²
NTrigs N Trig 5913760 Trigger
NHits N Hits 43013 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C9
Rate Rate 245.40 kHz/cm²
NTrigs N Trig 5913380 Trigger
NHits N Hits 22637 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C9
Rate Rate 158.10 kHz/cm²
NTrigs N Trig 5913488 Trigger
NHits N Hits 14584 Hits