Test Date: 2015-06-04 14:06
Chip 7
X-ray Calibration - Target Zn Method Spectrum Chip C7
Center Center of Peak 50.51 ± 0.14 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 4.88
Rate Rate 293.60 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C7
Center Center of Peak 104.24 ± 0.08 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 4.93
Rate Rate 465.90 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C7
Center Center of Peak 133.83 ± 0.12 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 4.45
Rate Rate 247.70 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C7
Center Center of Peak 152.92 ± 0.14 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 4.04
Rate Rate 158.20 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C7
Slope Slope 44.339 ± 0.135 nElectrons/VCal
Offset Offset 231.777 ± 16.561 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C7
Rate Rate 293.60 kHz/cm²
NTrigs N Trig 5913615 Trigger
NHits N Hits 27082 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C7
Rate Rate 465.90 kHz/cm²
NTrigs N Trig 5913760 Trigger
NHits N Hits 42982 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C7
Rate Rate 247.70 kHz/cm²
NTrigs N Trig 5913380 Trigger
NHits N Hits 22853 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C7
Rate Rate 158.20 kHz/cm²
NTrigs N Trig 5913488 Trigger
NHits N Hits 14591 Hits