Test Date: 2016-09-08 10:51
Analysis date: 2016-09-08 13:33
Chip 14
X-ray Calibration - Target Zn Method Spectrum Chip C14
Center Center of Peak 55.57 ± 0.07 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.68
Rate Rate 249.80 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C14
Center Center of Peak 105.33 ± 0.08 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 2.07
Rate Rate 399.80 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C14
Center Center of Peak 132.1 ± 0.1 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 4.6
Rate Rate 228.10 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C14
Center Center of Peak 149.0 ± 0.13 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 4.09
Rate Rate 148.90 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C14
Slope Slope 49.161 ± 0.073 nElectrons/VCal
Offset Offset -330.21 ± 6.881 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C14
Rate Rate 249.80 kHz/cm²
NTrigs N Trig 5916971 Trigger
NHits N Hits 23061 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C14
Rate Rate 399.80 kHz/cm²
NTrigs N Trig 5915780 Trigger
NHits N Hits 36895 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C14
Rate Rate 228.10 kHz/cm²
NTrigs N Trig 5916252 Trigger
NHits N Hits 21055 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C14
Rate Rate 148.90 kHz/cm²
NTrigs N Trig 5916197 Trigger
NHits N Hits 13744 Hits
MoReWeb-v1.0.2-10-gbc52a17 on branch psi46master