Test Date: 2016-09-07 11:25
Analysis date: 2016-09-07 13:22
Chip 14
X-ray Calibration - Target Zn Method Spectrum Chip C14
Center Center of Peak 47.74 ± 0.07 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.65
Rate Rate 255.70 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C14
Center Center of Peak 95.81 ± 0.07 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 3.02
Rate Rate 402.70 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C14
Center Center of Peak 121.1 ± 0.09 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 5.91
Rate Rate 229.80 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C14
Center Center of Peak 137.84 ± 0.11 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 5.57
Rate Rate 148.90 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C14
Slope Slope 51.484 ± 0.149 nElectrons/VCal
Offset Offset -77.529 ± 16.896 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C14
Rate Rate 255.70 kHz/cm²
NTrigs N Trig 5916108 Trigger
NHits N Hits 23601 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C14
Rate Rate 402.70 kHz/cm²
NTrigs N Trig 5913296 Trigger
NHits N Hits 37148 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C14
Rate Rate 229.80 kHz/cm²
NTrigs N Trig 5916665 Trigger
NHits N Hits 21213 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C14
Rate Rate 148.90 kHz/cm²
NTrigs N Trig 5916896 Trigger
NHits N Hits 13742 Hits
MoReWeb-v1.0.2-10-gbc52a17 on branch psi46master