Test Date: 2016-08-23 09:37
Analysis date: 2016-08-23 11:22
Chip 14
X-ray Calibration - Target Zn Method Spectrum Chip C14
Center Center of Peak 52.32 ± 0.08 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.73
Rate Rate 242.10 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C14
Center Center of Peak 107.97 ± 0.08 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 2.79
Rate Rate 401.40 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C14
Center Center of Peak 137.75 ± 0.1 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 5.23
Rate Rate 230.30 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C14
Center Center of Peak 158.17 ± 0.12 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 4.99
Rate Rate 151.10 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C14
Slope Slope 44.011 ± 0.063 nElectrons/VCal
Offset Offset 98.677 ± 6.282 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C14
Rate Rate 242.10 kHz/cm²
NTrigs N Trig 5917089 Trigger
NHits N Hits 22347 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C14
Rate Rate 401.40 kHz/cm²
NTrigs N Trig 5917323 Trigger
NHits N Hits 37051 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C14
Rate Rate 230.30 kHz/cm²
NTrigs N Trig 5915891 Trigger
NHits N Hits 21250 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C14
Rate Rate 151.10 kHz/cm²
NTrigs N Trig 5917296 Trigger
NHits N Hits 13944 Hits
MoReWeb-v1.0.2-10-gbc52a17 on branch psi46master