Test Date: 2016-08-10 11:12
Analysis date: 2016-08-10 13:30
Chip 14
X-ray Calibration - Target Zn Method Spectrum Chip C14
Center Center of Peak 49.29 ± 0.08 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.4
Rate Rate 246.20 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C14
Center Center of Peak 101.19 ± 0.07 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 3.74
Rate Rate 395.90 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C14
Center Center of Peak 129.33 ± 0.09 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 5.52
Rate Rate 225.80 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C14
Center Center of Peak 146.21 ± 0.12 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 4.89
Rate Rate 147.30 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C14
Slope Slope 47.018 ± 0.068 nElectrons/VCal
Offset Offset 86.974 ± 6.59 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C14
Rate Rate 246.20 kHz/cm²
NTrigs N Trig 5916819 Trigger
NHits N Hits 22726 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C14
Rate Rate 395.90 kHz/cm²
NTrigs N Trig 5916624 Trigger
NHits N Hits 36537 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C14
Rate Rate 225.80 kHz/cm²
NTrigs N Trig 5916710 Trigger
NHits N Hits 20839 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C14
Rate Rate 147.30 kHz/cm²
NTrigs N Trig 5916910 Trigger
NHits N Hits 13594 Hits
MoReWeb-v1.0.2-10-gbc52a17 on branch psi46master