Test Date: 2016-07-22 15:16
Analysis date: 2016-07-22 17:06
Chip 8
X-ray Calibration - Target Zn Method Spectrum Chip C8
Center |
Center of Peak |
54.62 ± 0.07 |
Vcal |
TargetEnergy |
Energy of target Zn |
8638.91 |
eV |
TargetNElectrons |
Energy of target Zn |
2399.7 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
1.57 |
|
Rate |
Rate |
307.00 |
kHz/cm² |
X-ray Calibration - Target Mo Method Spectrum Chip C8
Center |
Center of Peak |
105.14 ± 0.07 |
Vcal |
TargetEnergy |
Energy of target Mo |
17479.37 |
eV |
TargetNElectrons |
Energy of target Mo |
4855.38 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
3.16 |
|
Rate |
Rate |
450.40 |
kHz/cm² |
X-ray Calibration - Target Ag Method Spectrum Chip C8
Center |
Center of Peak |
132.91 ± 0.1 |
Vcal |
TargetEnergy |
Energy of target Ag |
22162.92 |
eV |
TargetNElectrons |
Energy of target Ag |
6156.37 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
4.72 |
|
Rate |
Rate |
241.40 |
kHz/cm² |
X-ray Calibration - Target Sn Method Spectrum Chip C8
Center |
Center of Peak |
149.84 ± 0.12 |
Vcal |
TargetEnergy |
Energy of target Sn |
25271.36 |
eV |
TargetNElectrons |
Energy of target Sn |
7019.82 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
4.73 |
|
Rate |
Rate |
153.90 |
kHz/cm² |
X-ray Calibration - Vcal Calibration Method Spectrum Chip C8
Slope |
Slope |
48.322 ± 0.058 |
nElectrons/VCal |
Offset |
Offset |
-236.896 ± 5.96 |
nElectrons |
X-ray Hit Map - Target Zn Method Spectrum Chip C8
Rate |
Rate |
307.00 |
kHz/cm² |
NTrigs |
N Trig |
5917073 |
Trigger |
NHits |
N Hits |
28339 |
Hits |
X-ray Hit Map - Target Mo Method Spectrum Chip C8
Rate |
Rate |
450.40 |
kHz/cm² |
NTrigs |
N Trig |
5916229 |
Trigger |
NHits |
N Hits |
41572 |
Hits |
X-ray Hit Map - Target Ag Method Spectrum Chip C8
Rate |
Rate |
241.40 |
kHz/cm² |
NTrigs |
N Trig |
5916934 |
Trigger |
NHits |
N Hits |
22280 |
Hits |
X-ray Hit Map - Target Sn Method Spectrum Chip C8
Rate |
Rate |
153.90 |
kHz/cm² |
NTrigs |
N Trig |
5916863 |
Trigger |
NHits |
N Hits |
14202 |
Hits |
MoReWeb-v1.0.2-10-gbc52a17 on branch psi46master