Test Date: 2016-06-09 09:50
Analysis date: 2016-06-10 11:30
XrayQualification M2241
Module ID Test Date Analysis Test Type Grade Pixel Defects ROCs < 1% ROCs > 1% ROCs > 4% Noise Trimming PHCalibration I(150V) I_rec(150V) IV Slope Temperature initial Current Comments
M2241 2016-06-09 09:50 2016-06-09 12:10 XRayHRQualification A 48 16 0 0 4 None None None None None None None
M2241 2016-06-09 09:50 2016-06-09 12:10 XrayCalibration_Spectrum None None None None None None None None None None None None None None
M2241 ModuleQualification_SumOfCurrents
M2241 XRayHRQualification

Overview

X-ray Calibration - Spectrum
Slope avrg Slope 45.577375

Overview

MoReWeb-v1.0.0-5-g82d9ff6 on branch psi46master