Test Date: 2016-05-04 10:00
Analysis date: 2016-05-26 16:25
Chip 8
X-ray Calibration - Target Zn Method Spectrum Chip C8
Center Center of Peak 50.02 ± 0.09 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.33
Rate Rate 292.70 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C8
Center Center of Peak 102.89 ± 0.07 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 2.7
Rate Rate 468.20 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C8
Center Center of Peak 129.5 ± 0.1 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 4.53
Rate Rate 248.90 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C8
Center Center of Peak 148.56 ± 0.13 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 4.33
Rate Rate 157.40 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C8
Slope Slope 47.035 ± 0.064 nElectrons/VCal
Offset Offset 35.949 ± 6.772 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C8
Rate Rate 292.70 kHz/cm²
NTrigs N Trig 5916952 Trigger
NHits N Hits 27018 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C8
Rate Rate 468.20 kHz/cm²
NTrigs N Trig 5916645 Trigger
NHits N Hits 43214 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C8
Rate Rate 248.90 kHz/cm²
NTrigs N Trig 5917260 Trigger
NHits N Hits 22977 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C8
Rate Rate 157.40 kHz/cm²
NTrigs N Trig 5916862 Trigger
NHits N Hits 14528 Hits