Test Date: 2016-04-12 09:31
Analysis date: 2016-05-26 14:10
Chip 9
X-ray Calibration - Target Zn Method Spectrum Chip C9
Center Center of Peak 51.24 ± 0.09 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.38
Rate Rate 296.60 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C9
Center Center of Peak 102.56 ± 0.07 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 2.64
Rate Rate 443.30 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C9
Center Center of Peak 129.72 ± 0.11 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 3.77
Rate Rate 235.00 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C9
Center Center of Peak 147.54 ± 0.15 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 3.08
Rate Rate 150.00 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C9
Slope Slope 47.863 ± 0.081 nElectrons/VCal
Offset Offset -53.008 ± 7.903 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C9
Rate Rate 296.60 kHz/cm²
NTrigs N Trig 5916283 Trigger
NHits N Hits 27373 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C9
Rate Rate 443.30 kHz/cm²
NTrigs N Trig 5916632 Trigger
NHits N Hits 40918 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C9
Rate Rate 235.00 kHz/cm²
NTrigs N Trig 5916271 Trigger
NHits N Hits 21689 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C9
Rate Rate 150.00 kHz/cm²
NTrigs N Trig 5916371 Trigger
NHits N Hits 13840 Hits
MoReWeb-v1.0.0-5-g82d9ff6 on branch psi46master