Test Date: 2016-03-24 13:32
Analysis date: 2016-05-26 13:03
Chip 14
X-ray Calibration - Target Zn Method Spectrum Chip C14
Center Center of Peak 53.09 ± 0.07 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.55
Rate Rate 233.30 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C14
Center Center of Peak 105.56 ± 0.08 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 2.28
Rate Rate 380.90 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C14
Center Center of Peak 132.88 ± 0.11 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 4.59
Rate Rate 217.90 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C14
Center Center of Peak 151.04 ± 0.13 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 3.97
Rate Rate 143.20 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C14
Slope Slope 47.598 ± 0.149 nElectrons/VCal
Offset Offset -168.953 ± 18.421 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C14
Rate Rate 233.30 kHz/cm²
NTrigs N Trig 5913848 Trigger
NHits N Hits 21520 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C14
Rate Rate 380.90 kHz/cm²
NTrigs N Trig 5913893 Trigger
NHits N Hits 35139 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C14
Rate Rate 217.90 kHz/cm²
NTrigs N Trig 5913929 Trigger
NHits N Hits 20105 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C14
Rate Rate 143.20 kHz/cm²
NTrigs N Trig 5913856 Trigger
NHits N Hits 13214 Hits
MoReWeb-v1.0.0-5-g82d9ff6 on branch psi46master