Test Date: 2016-02-24 09:58
Analysis date: 2016-05-26 10:46
Chip 14
X-ray Calibration - Target Zn Method Spectrum Chip C14
Center Center of Peak 51.75 ± 0.08 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.5
Rate Rate 247.00 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C14
Center Center of Peak 104.7 ± 0.08 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 2.57
Rate Rate 389.80 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C14
Center Center of Peak 132.7 ± 0.1 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 4.66
Rate Rate 221.80 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C14
Center Center of Peak 151.27 ± 0.14 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 4.18
Rate Rate 145.50 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C14
Slope Slope 46.473 ± 0.146 nElectrons/VCal
Offset Offset -10.404 ± 17.894 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C14
Rate Rate 247.00 kHz/cm²
NTrigs N Trig 5914380 Trigger
NHits N Hits 22789 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C14
Rate Rate 389.80 kHz/cm²
NTrigs N Trig 5914130 Trigger
NHits N Hits 35961 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C14
Rate Rate 221.80 kHz/cm²
NTrigs N Trig 5914312 Trigger
NHits N Hits 20463 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C14
Rate Rate 145.50 kHz/cm²
NTrigs N Trig 5914388 Trigger
NHits N Hits 13427 Hits
MoReWeb-v1.0.0-5-g82d9ff6 on branch psi46master