Test Date: 2016-02-11 16:37
Analysis date: 2016-05-26 10:15
Chip 8
X-ray Calibration - Target Zn Method Spectrum Chip C8
Center |
Center of Peak |
50.46 ± 0.1 |
Vcal |
TargetEnergy |
Energy of target Zn |
8638.91 |
eV |
TargetNElectrons |
Energy of target Zn |
2399.7 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
1.51 |
|
Rate |
Rate |
300.10 |
kHz/cm² |
X-ray Calibration - Target Mo Method Spectrum Chip C8
Center |
Center of Peak |
105.27 ± 0.07 |
Vcal |
TargetEnergy |
Energy of target Mo |
17479.37 |
eV |
TargetNElectrons |
Energy of target Mo |
4855.38 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
2.86 |
|
Rate |
Rate |
465.00 |
kHz/cm² |
X-ray Calibration - Target Ag Method Spectrum Chip C8
Center |
Center of Peak |
133.77 ± 0.1 |
Vcal |
TargetEnergy |
Energy of target Ag |
22162.92 |
eV |
TargetNElectrons |
Energy of target Ag |
6156.37 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
4.69 |
|
Rate |
Rate |
246.10 |
kHz/cm² |
X-ray Calibration - Target Sn Method Spectrum Chip C8
Center |
Center of Peak |
152.46 ± 0.13 |
Vcal |
TargetEnergy |
Energy of target Sn |
25271.36 |
eV |
TargetNElectrons |
Energy of target Sn |
7019.82 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
4.76 |
|
Rate |
Rate |
156.70 |
kHz/cm² |
X-ray Calibration - Vcal Calibration Method Spectrum Chip C8
Slope |
Slope |
45.803 ± 0.129 |
nElectrons/VCal |
Offset |
Offset |
33.012 ± 15.813 |
nElectrons |
X-ray Hit Map - Target Zn Method Spectrum Chip C8
Rate |
Rate |
300.10 |
kHz/cm² |
NTrigs |
N Trig |
5916750 |
Trigger |
NHits |
N Hits |
27696 |
Hits |
X-ray Hit Map - Target Mo Method Spectrum Chip C8
Rate |
Rate |
465.00 |
kHz/cm² |
NTrigs |
N Trig |
5916692 |
Trigger |
NHits |
N Hits |
42922 |
Hits |
X-ray Hit Map - Target Ag Method Spectrum Chip C8
Rate |
Rate |
246.10 |
kHz/cm² |
NTrigs |
N Trig |
5916629 |
Trigger |
NHits |
N Hits |
22714 |
Hits |
X-ray Hit Map - Target Sn Method Spectrum Chip C8
Rate |
Rate |
156.70 |
kHz/cm² |
NTrigs |
N Trig |
5916572 |
Trigger |
NHits |
N Hits |
14466 |
Hits |