Test Date: 2015-12-16 10:27
Analysis date: 2016-05-26 07:24
Chip 14
X-ray Calibration - Target Zn Method Spectrum Chip C14
Center Center of Peak 52.31 ± 0.09 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.37
Rate Rate 209.60 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C14
Center Center of Peak 103.04 ± 0.09 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 1.62
Rate Rate 360.10 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C14
Center Center of Peak 129.53 ± 0.11 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 3.7
Rate Rate 210.50 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C14
Center Center of Peak 146.73 ± 0.14 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 3.06
Rate Rate 141.90 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C14
Slope Slope 49.433 ± 0.175 nElectrons/VCal
Offset Offset -239.944 ± 21.258 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C14
Rate Rate 209.60 kHz/cm²
NTrigs N Trig 5916308 Trigger
NHits N Hits 19346 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C14
Rate Rate 360.10 kHz/cm²
NTrigs N Trig 5916118 Trigger
NHits N Hits 33237 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C14
Rate Rate 210.50 kHz/cm²
NTrigs N Trig 5916120 Trigger
NHits N Hits 19431 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C14
Rate Rate 141.90 kHz/cm²
NTrigs N Trig 5916586 Trigger
NHits N Hits 13094 Hits
MoReWeb-v1.0.0-5-g82d9ff6 on branch psi46master