Test Date: 2015-12-08 13:49
Analysis date: 2016-05-26 06:54
Chip 14
X-ray Calibration - Target Zn Method Spectrum Chip C14
Center Center of Peak 52.54 ± 0.09 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.43
Rate Rate 221.10 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C14
Center Center of Peak 107.02 ± 0.08 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 2.55
Rate Rate 373.70 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C14
Center Center of Peak 135.56 ± 0.1 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 4.61
Rate Rate 216.20 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C14
Center Center of Peak 154.1 ± 0.14 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 4.62
Rate Rate 141.20 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C14
Slope Slope 45.854 ± 0.142 nElectrons/VCal
Offset Offset -53.454 ± 17.792 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C14
Rate Rate 221.10 kHz/cm²
NTrigs N Trig 5914668 Trigger
NHits N Hits 20397 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C14
Rate Rate 373.70 kHz/cm²
NTrigs N Trig 5914994 Trigger
NHits N Hits 34484 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C14
Rate Rate 216.20 kHz/cm²
NTrigs N Trig 5914758 Trigger
NHits N Hits 19951 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C14
Rate Rate 141.20 kHz/cm²
NTrigs N Trig 5915017 Trigger
NHits N Hits 13028 Hits
MoReWeb-v1.0.0-5-g82d9ff6 on branch psi46master