Test Date: 2015-10-20 15:25
Analysis date: 2016-05-26 05:55
Chip 14
X-ray Calibration - Target Zn Method Spectrum Chip C14
Center Center of Peak 49.15 ± 0.09 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.35
Rate Rate 226.50 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C14
Center Center of Peak 100.0 ± 0.08 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 2.42
Rate Rate 371.70 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C14
Center Center of Peak 127.19 ± 0.11 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 3.57
Rate Rate 217.60 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C14
Center Center of Peak 145.3 ± 0.14 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 3.5
Rate Rate 141.20 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C14
Slope Slope 47.799 ± 0.156 nElectrons/VCal
Offset Offset 75.736 ± 18.244 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C14
Rate Rate 226.50 kHz/cm²
NTrigs N Trig 5914992 Trigger
NHits N Hits 20902 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C14
Rate Rate 371.70 kHz/cm²
NTrigs N Trig 5914834 Trigger
NHits N Hits 34300 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C14
Rate Rate 217.60 kHz/cm²
NTrigs N Trig 5915139 Trigger
NHits N Hits 20075 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C14
Rate Rate 141.20 kHz/cm²
NTrigs N Trig 5914997 Trigger
NHits N Hits 13033 Hits