Test Date: 2015-10-20 15:25
Analysis date: 2016-05-26 03:46
Chip 14
X-ray Calibration - Target Zn Method Spectrum Chip C14
Center Center of Peak 49.62 ± 0.07 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.15
Rate Rate 259.60 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C14
Center Center of Peak 102.44 ± 0.07 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 3.42
Rate Rate 409.90 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C14
Center Center of Peak 130.74 ± 0.1 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 5.44
Rate Rate 234.50 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C14
Center Center of Peak 148.47 ± 0.11 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 5.15
Rate Rate 151.20 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C14
Slope Slope 46.369 ± 0.064 nElectrons/VCal
Offset Offset 100.554 ± 5.921 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C14
Rate Rate 259.60 kHz/cm²
NTrigs N Trig 5917856 Trigger
NHits N Hits 23968 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C14
Rate Rate 409.90 kHz/cm²
NTrigs N Trig 5917673 Trigger
NHits N Hits 37836 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C14
Rate Rate 234.50 kHz/cm²
NTrigs N Trig 5917916 Trigger
NHits N Hits 21647 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C14
Rate Rate 151.20 kHz/cm²
NTrigs N Trig 5917613 Trigger
NHits N Hits 13959 Hits