Test Date: 2015-08-24 08:08
Analysis date: 2016-05-26 02:17
Chip 14
X-ray Calibration - Target Zn Method Spectrum Chip C14
Center Center of Peak 51.49 ± 0.11 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.49
Rate Rate 200.70 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C14
Center Center of Peak 103.97 ± 0.09 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 2.26
Rate Rate 364.70 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C14
Center Center of Peak 132.28 ± 0.11 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 4.45
Rate Rate 212.90 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C14
Center Center of Peak 150.45 ± 0.15 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 3.82
Rate Rate 136.80 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C14
Slope Slope 46.597 ± 0.075 nElectrons/VCal
Offset Offset 3.436 ± 8.183 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C14
Rate Rate 200.70 kHz/cm²
NTrigs N Trig 5919390 Trigger
NHits N Hits 18530 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C14
Rate Rate 364.70 kHz/cm²
NTrigs N Trig 5919667 Trigger
NHits N Hits 33683 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C14
Rate Rate 212.90 kHz/cm²
NTrigs N Trig 5919914 Trigger
NHits N Hits 19665 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C14
Rate Rate 136.80 kHz/cm²
NTrigs N Trig 5919454 Trigger
NHits N Hits 12629 Hits
MoReWeb-v1.0.0-5-g82d9ff6 on branch psi46master