Test Date: 2015-08-13 17:13
Analysis date: 2016-05-26 01:13
Chip 8
X-ray Calibration - Target Zn Method Spectrum Chip C8
Center |
Center of Peak |
51.76 ± 0.06 |
Vcal |
TargetEnergy |
Energy of target Zn |
8638.91 |
eV |
TargetNElectrons |
Energy of target Zn |
2399.7 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
2.57 |
|
Rate |
Rate |
337.00 |
kHz/cm² |
X-ray Calibration - Target Mo Method Spectrum Chip C8
Center |
Center of Peak |
103.46 ± 0.07 |
Vcal |
TargetEnergy |
Energy of target Mo |
17479.37 |
eV |
TargetNElectrons |
Energy of target Mo |
4855.38 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
4.19 |
|
Rate |
Rate |
483.60 |
kHz/cm² |
X-ray Calibration - Target Ag Method Spectrum Chip C8
Center |
Center of Peak |
131.38 ± 0.09 |
Vcal |
TargetEnergy |
Energy of target Ag |
22162.92 |
eV |
TargetNElectrons |
Energy of target Ag |
6156.37 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
5.89 |
|
Rate |
Rate |
261.80 |
kHz/cm² |
X-ray Calibration - Target Sn Method Spectrum Chip C8
Center |
Center of Peak |
148.9 ± 0.12 |
Vcal |
TargetEnergy |
Energy of target Sn |
25271.36 |
eV |
TargetNElectrons |
Energy of target Sn |
7019.82 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
5.0 |
|
Rate |
Rate |
160.30 |
kHz/cm² |
X-ray Calibration - Vcal Calibration Method Spectrum Chip C8
Slope |
Slope |
47.39 ± 0.05 |
nElectrons/VCal |
Offset |
Offset |
-52.804 ± 4.96 |
nElectrons |
X-ray Hit Map - Target Zn Method Spectrum Chip C8
Rate |
Rate |
337.00 |
kHz/cm² |
NTrigs |
N Trig |
5920352 |
Trigger |
NHits |
N Hits |
31127 |
Hits |
X-ray Hit Map - Target Mo Method Spectrum Chip C8
Rate |
Rate |
483.60 |
kHz/cm² |
NTrigs |
N Trig |
5920377 |
Trigger |
NHits |
N Hits |
44660 |
Hits |
X-ray Hit Map - Target Ag Method Spectrum Chip C8
Rate |
Rate |
261.80 |
kHz/cm² |
NTrigs |
N Trig |
5920432 |
Trigger |
NHits |
N Hits |
24175 |
Hits |
X-ray Hit Map - Target Sn Method Spectrum Chip C8
Rate |
Rate |
160.30 |
kHz/cm² |
NTrigs |
N Trig |
5920606 |
Trigger |
NHits |
N Hits |
14806 |
Hits |
MoReWeb-v1.0.0-5-g82d9ff6 on branch psi46master