Test Date: 2015-08-11 15:16
Analysis date: 2016-05-26 00:59
Chip 8
X-ray Calibration - Target Zn Method Spectrum Chip C8
Center Center of Peak 47.4 ± 0.08 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.56
Rate Rate 294.80 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C8
Center Center of Peak 98.52 ± 0.07 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 2.47
Rate Rate 453.70 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C8
Center Center of Peak 125.12 ± 0.1 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 3.61
Rate Rate 241.80 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C8
Center Center of Peak 143.05 ± 0.12 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 3.15
Rate Rate 152.10 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C8
Slope Slope 48.682 ± 0.141 nElectrons/VCal
Offset Offset 60.182 ± 16.212 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C8
Rate Rate 294.80 kHz/cm²
NTrigs N Trig 5916655 Trigger
NHits N Hits 27211 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C8
Rate Rate 453.70 kHz/cm²
NTrigs N Trig 5916919 Trigger
NHits N Hits 41878 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C8
Rate Rate 241.80 kHz/cm²
NTrigs N Trig 5916649 Trigger
NHits N Hits 22322 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C8
Rate Rate 152.10 kHz/cm²
NTrigs N Trig 5916757 Trigger
NHits N Hits 14038 Hits