Test Date: 2015-08-12 14:10
Analysis date: 2016-05-26 00:17
Chip 9
X-ray Calibration - Target Zn Method Spectrum Chip C9
Center Center of Peak 56.57 ± 0.08 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.42
Rate Rate 275.20 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C9
Center Center of Peak 111.46 ± 0.07 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 3.36
Rate Rate 428.80 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C9
Center Center of Peak 140.13 ± 0.1 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 4.61
Rate Rate 229.40 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C9
Center Center of Peak 159.06 ± 0.14 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 4.15
Rate Rate 147.90 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C9
Slope Slope 45.441 ± 0.132 nElectrons/VCal
Offset Offset -209.713 ± 16.818 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C9
Rate Rate 275.20 kHz/cm²
NTrigs N Trig 5918306 Trigger
NHits N Hits 25407 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C9
Rate Rate 428.80 kHz/cm²
NTrigs N Trig 5918310 Trigger
NHits N Hits 39588 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C9
Rate Rate 229.40 kHz/cm²
NTrigs N Trig 5918641 Trigger
NHits N Hits 21183 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C9
Rate Rate 147.90 kHz/cm²
NTrigs N Trig 5918821 Trigger
NHits N Hits 13652 Hits