Test Date: 2015-08-12 14:10
Analysis date: 2016-05-25 23:29
Chip 8
X-ray Calibration - Target Zn Method Spectrum Chip C8
Center Center of Peak 53.01 ± 0.06 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 1.56
Rate Rate 334.60 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C8
Center Center of Peak 104.05 ± 0.07 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 2.03
Rate Rate 488.50 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C8
Center Center of Peak 131.48 ± 0.1 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 3.88
Rate Rate 256.00 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C8
Center Center of Peak 149.63 ± 0.13 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 4.12
Rate Rate 160.40 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C8
Slope Slope 47.47 ± 0.139 nElectrons/VCal
Offset Offset -84.046 ± 16.724 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C8
Rate Rate 334.60 kHz/cm²
NTrigs N Trig 5919021 Trigger
NHits N Hits 30900 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C8
Rate Rate 488.50 kHz/cm²
NTrigs N Trig 5918879 Trigger
NHits N Hits 45101 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C8
Rate Rate 256.00 kHz/cm²
NTrigs N Trig 5919388 Trigger
NHits N Hits 23643 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C8
Rate Rate 160.40 kHz/cm²
NTrigs N Trig 5918910 Trigger
NHits N Hits 14813 Hits
MoReWeb-v1.0.0-5-g82d9ff6 on branch psi46master