Test Date: 2015-11-23 13:32
Analysis date: 2015-11-23 18:15
Chip 8
X-ray Calibration - Target Zn Method Spectrum Chip C8
Center |
Center of Peak |
52.63 ± 0.13 |
Vcal |
TargetEnergy |
Energy of target Zn |
8638.91 |
eV |
TargetNElectrons |
Energy of target Zn |
2399.7 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
1.16 |
|
Rate |
Rate |
158.40 |
kHz/cm² |
X-ray Calibration - Target Mo Method Spectrum Chip C8
Center |
Center of Peak |
107.2 ± 0.08 |
Vcal |
TargetEnergy |
Energy of target Mo |
17479.37 |
eV |
TargetNElectrons |
Energy of target Mo |
4855.38 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
2.06 |
|
Rate |
Rate |
410.20 |
kHz/cm² |
X-ray Calibration - Target Ag Method Spectrum Chip C8
Center |
Center of Peak |
135.06 ± 0.11 |
Vcal |
TargetEnergy |
Energy of target Ag |
22162.92 |
eV |
TargetNElectrons |
Energy of target Ag |
6156.37 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
3.48 |
|
Rate |
Rate |
226.80 |
kHz/cm² |
X-ray Calibration - Target Sn Method Spectrum Chip C8
Center |
Center of Peak |
154.41 ± 0.15 |
Vcal |
TargetEnergy |
Energy of target Sn |
25271.36 |
eV |
TargetNElectrons |
Energy of target Sn |
7019.82 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
3.52 |
|
Rate |
Rate |
140.10 |
kHz/cm² |
X-ray Calibration - Vcal Calibration Method Spectrum Chip C8
Slope |
Slope |
46.108 ± 0.15 |
nElectrons/VCal |
Offset |
Offset |
-84.497 ± 18.562 |
nElectrons |
X-ray Hit Map - Target Zn Method Spectrum Chip C8
Rate |
Rate |
158.40 |
kHz/cm² |
NTrigs |
N Trig |
5922136 |
Trigger |
NHits |
N Hits |
14632 |
Hits |
X-ray Hit Map - Target Mo Method Spectrum Chip C8
Rate |
Rate |
410.20 |
kHz/cm² |
NTrigs |
N Trig |
5922181 |
Trigger |
NHits |
N Hits |
37894 |
Hits |
X-ray Hit Map - Target Ag Method Spectrum Chip C8
Rate |
Rate |
226.80 |
kHz/cm² |
NTrigs |
N Trig |
5921732 |
Trigger |
NHits |
N Hits |
20952 |
Hits |
X-ray Hit Map - Target Sn Method Spectrum Chip C8
Rate |
Rate |
140.10 |
kHz/cm² |
NTrigs |
N Trig |
5921877 |
Trigger |
NHits |
N Hits |
12938 |
Hits |
MoReWeb-v0.6.7-73-g24fed82
on branch dev-v0.7.0