Directory shortTests/M0077-071210.11:07/T-10a ModuleNr TestNr M0077 T-10a Defects 2 0 - - - PerfDefects - - 0 0 0 ROCS with defects > 1% 0 0 0 Missing histograms 0 Tested yes on Mon Dec 10 11:44:53 2007 phCalibration yes on Mon Dec 10 11:36:43 2007 Temp -10.015 0.025425 Soll -10 Thermal cycling no -100 -100 Test duration 1.08333 dtlScan 12 SwitchOn 0.397988 Current 0.0225782 LogErrors 0 Gain 3.08638733333333 0.0560108866666667 Pedestal 363.056266666667 19.1997533333333 Parameter1 1.23842 0.0397818666666667 Gains good Peds good Par1 good I 150 0.273239 I150/I100 0.000000 iv datapoints 1 Grade A DEAD 0 0 MASK - 0 PHCAL 0 0 RelGainWidth 0 0 PedSpread 0 0 MeanParameter1 0 0 I150V 0 0 RATIO 0.68655085077942 position 30135 retest GRADE A shortTest GRADE A fullTest GRADE A FINAL DB-GRADE A old shortTest GRADE A old fullTest GRADE A