Directory M1037-070919.16:00/T-10a ModuleNr TestNr M1037 T-10a Defects 0 0 10 0 8553 PerfDefects 2 1 1 1 7 ROCS with defects > 1% 3 0 3 Missing histograms 0 Tested yes on Wed Sep 19 16:49:29 2007 Trimming yes on Sat Nov 1 08:08:56 2008 phCalibration no Temp -9.99714 0.0201527 Soll -10 Thermal cycling yes 2.772 9.49619 Test duration 3.88333 dtlScan 19 SwitchOn 0.63377 Current 0.11491 LogErrors 0 SCurve 182.377571428571 23.2079142857143 Threshold 69.2163 1.56545142857143 Gain 4.17422428571429 0.167336571428571 Pedestal 122.720214285714 30.4527571428571 Parameter1 17.5314591836735 4.35039387755102 SCurves good Thresholds good Gains good Peds good Par1 good TBM1 0 TBM2 0 I 150 0.000000 I150/I100 0.000000 iv datapoints 0 Grade C DEAD 0 0 MASK - 0 BUMPS 0 0 TRIMS 0 0 ADDRESS 0 3 NOISE 0 0 TTHR 0 0 PHCAL 0 0 Noise 0 0 VcalThrWidth 0 0 RelGainWidth 0 0 PedSpread 0 0 MeanParameter1 0 0 I150V 0 0 Iratio 0 0 RATIO 3.88581750747159 position 20031 Half-Module b Regrading: Decoding problems are test artefact, maybe sampling point not ok, test with scope shows no problems Regrade B retest GRADE - shortTest GRADE A fullTest GRADE C FINAL DB-GRADE B old shortTest GRADE B old fullTest GRADE B