Directory M0701-070410.17:10/T-10b ModuleNr TestNr M0701 T-10b Defects 0 0 1 0 0 PerfDefects 0 0 0 0 0 ROCS with defects > 1% 0 0 0 Missing histograms 0 Tested yes on Tue Apr 10 20:39:48 2007 Trimming yes on Tue Apr 10 20:22:06 2007 phCalibration yes on Tue Apr 10 20:12:42 2007 Temp -10 -100 Soll -10 Thermal cycling yes -100 -100 Test duration -100 dtlScan 11 SwitchOn 0.444353 Current 0.0610023 LogErrors 0 SCurve 166.383466666667 21.1032666666667 Threshold 64.6641533333333 1.47578066666667 Gain 2.457858 0.0879698066666667 Pedestal 187.359626666667 25.2494733333333 Parameter1 12.4906417777778 1.68329822222222 SCurves good Thresholds good Gains good Peds good Par1 good TBM1 0 TBM2 0 I 150 0.283845 I150/I100 1.143322 iv datapoints 80 Grade A ModuleDefects 1 ModuleFunctDefects 1 ModulePerfDefects 0 ModulePHDefects 0 DEAD 0 0 MASK - 0 BUMPS 0 0 TRIMS 0 0 ADDRESS 0 0 NOISE 0 0 TTHR 0 0 PHCAL 0 0 Noise 0 0 VcalThrWidth 0 0 RelGainWidth 0 0 PedSpread 0 0 MeanParameter1 0 0 I150V 0 0 Iratio 0 0 RATIO 0 position - retest GRADE - shortTest GRADE - fullTest GRADE C FINAL DB-GRADE C old shortTest GRADE - old fullTest GRADE C