Directory M0099-070115.16:42/T+17a ModuleNr TestNr M0099 T+17a Defects 0 0 9 0 0 PerfDefects 1 9 0 0 0 ROCS with defects > 1% 0 0 0 Missing histograms 0 Tested yes on Mon Jan 15 23:32:43 2007 Trimming yes on Mon Jan 15 23:05:14 2007 phCalibration yes on Mon Jan 15 22:52:45 2007 Temp 16.8148 0.298376 Soll +17 Thermal cycling yes 3.03726 9.75892 Test duration 7.33333 dtlScan 8 SwitchOn 0.200186 Current 0.191118 LogErrors 0 SCurve 166.564933333333 16.6036533333333 Threshold 64.67648 1.38656133333333 Gain 2.34932866666667 0.0540244733333333 Pedestal 182.347466666667 22.3304866666667 Parameter1 12.1564977777778 1.48869911111111 SCurves good Thresholds good Gains good Peds good Par1 good TBM1 0 TBM2 0 I 150 0.198468 I150/I100 1.269754 iv datapoints 104 Grade A ModuleDefects 18 ModuleFunctDefects 9 ModulePerfDefects 10 ModulePHDefects 0 DEAD 0 0 MASK - 0 BUMPS 0 0 TRIMS 0 0 ADDRESS 0 0 NOISE 0 0 TTHR 0 0 PHCAL 0 0 Noise 0 0 VcalThrWidth 0 0 RelGainWidth 0 0 PedSpread 0 0 MeanParameter1 0 0 I150V 0 0 Iratio 0 0 RATIO 1.01463208174618 position 20047 retest GRADE A shortTest GRADE A fullTest GRADE A FINAL DB-GRADE A old shortTest GRADE A old fullTest GRADE A